Image of Sistem pendinginan coolant menggunakan termoelektrik dengan unit pembuang panas heat pipe

Tugas Akhir Mesin

Sistem pendinginan coolant menggunakan termoelektrik dengan unit pembuang panas heat pipe

Zefri Ardian - Nama Orang;

This study examines thermoelectrics to cool the flowing coolant inside a water block. There were two identical thermoelectrics with a type of TEC2-25408 and dimension of 40 mm x 40 mm x 3.74 mm. The cold side of the thermoelectric was affixed to the top surface of water block, while the hot side of the thermoelectric was attached to the heat pipe. The mass flow rates of the coolant were varied, i.e. 1 g/s, 1.5 g/s, and 2 g/s. All temperatures were measured using calibrated K-type thermocouples with an uncertainty of ± 0.5°C. The experiment was observed for about 5 hours. All data were recorded using the data logger DAQ MX 9714 NI that was connected to the PV with LabView program. The results show that at the coolant mass flow rate of 1 g/s and the ambient temperature of 30.57°C, the cold side and hot side temperatures are 21.83°C and 51.41°C, the inlet and outlet water block temperatures are 31.01°C and 27.01°C. The COPs of the thermoelectric and system are 0.183 and 0.138. While at the coolant mass flow rate of 1.5 g/s and the ambient temperature of 30.81°C, the cold side and the hot side temperatures of the thermoelectric are 23.32°C and 50.83°C, the inlet and outlet water block temperatures are 31.61°C and 28.4°C. While the COPs of thermoelectric and system are 0.212 and 0.159. Then at the coolant mass flow rate of 2 g/s and the ambient temperature of 30.84°C, the cold side and hot side temperatures of the thermoelectric are 23.32°C and 50.83°C, the inlet and outlet water block temperatures are 30.94°C and 28.37°C. While the COPs of the thermoelectric and system are 0.215 and 0.162. Hence, increasing the mass flow rate of the coolant elevates the outlet temperature of the water block and increases the COPs of the thermoelectric and system.


Ketersediaan

Tidak ada salinan data

Informasi Detail
Judul Seri
Heat Pipe
No. Panggil
629.25 [21] Zef.s
Penerbit
UNRAM : Fakultas Teknik Unram., 2018
Deskripsi Fisik
xiv,95 Hlm; Illus; 21x29 cm
Bahasa
Indonesia
ISBN/ISSN
-
Klasifikasi
629.25 [21]
Tipe Isi
other
Tipe Media
other
Tipe Pembawa
-
Edisi
Edisi 1 Jilid 1
Subjek
Sistem pendinginan
Thermoelectric module
Mass flow rate of coolant
Temperature COP
Info Detail Spesifik
Termoelektrik
Pernyataan Tanggungjawab
Zefri Ardian
Versi lain/terkait

Tidak tersedia versi lain

Lampiran Berkas
  • Sistem pendinginan coolant menggunakan termoelektrik dengan unit pembuang panas heat pipe
Komentar

Anda harus login sebelum memberikan komentar

Perpustakaan Fakultas Teknik
  • Informasi
  • Layanan
  • Pustakawan
  • Area Anggota

Tentang Kami

Ruang Baca Fakultas Teknik

Kami menyedian Buku ajar ilmu teknik dan Tugas Akhir mahaiswa Fakultas Teknik Universitas Mataram

Cari

masukkan satu atau lebih kata kunci dari judul, pengarang, atau subjek

Donasi untuk SLiMS Kontribusi untuk SLiMS?

© 2025 — Senayan Developer Community

Ditenagai oleh SLiMS
Pilih subjek yang menarik bagi Anda
  • Karya Umum
  • Filsafat
  • Agama
  • Ilmu-ilmu Sosial
  • Bahasa
  • Ilmu-ilmu Murni
  • Ilmu-ilmu Terapan
  • Kesenian, Hiburan, dan Olahraga
  • Kesusastraan
  • Geografi dan Sejarah
Icons made by Freepik from www.flaticon.com
Pencarian Spesifik