Perpustakaan Fakultas Teknik

Universitas Mataram

  • Beranda
  • Informasi
  • Berita
  • Bantuan
  • Pustakawan
  • Area Anggota
  • Pilih Bahasa :
    Bahasa Arab Bahasa Bengal Bahasa Brazil Portugis Bahasa Inggris Bahasa Spanyol Bahasa Jerman Bahasa Indonesia Bahasa Jepang Bahasa Melayu Bahasa Persia Bahasa Rusia Bahasa Thailand Bahasa Turki Bahasa Urdu

Pencarian berdasarkan :

SEMUA Pengarang Subjek ISBN/ISSN Pencarian Spesifik

Pencarian terakhir:

{{tmpObj[k].text}}
Image of PENGARUH JARAK ANTAR PLATE PADA PERMEABILITAS ALIRAN BIOFLUIDA PADA PERMUKAAN MEMBRAN PERMEABLE. Effect Of Distance Between Plates On The Permeability Of Biofluida Flow On The Surface Of Permeable Membrane

Tugas Akhir Mesin

PENGARUH JARAK ANTAR PLATE PADA PERMEABILITAS ALIRAN BIOFLUIDA PADA PERMUKAAN MEMBRAN PERMEABLE. Effect Of Distance Between Plates On The Permeability Of Biofluida Flow On The Surface Of Permeable Membrane

Salim AlQadri - Nama Orang;

Chronic kidney failure is one of domestic health problems faced by Indonesia with the increasing number and with the high cost therapy. One of the therapy is with haemodialysis whose performance depends on dialyzer effectiveness. The effectiveness of dialyzer depends on the mass transfer through membrane. This research is aimed to know the influence of distance to the plate in di diffusion NaCl and ion OH. experiment was conducted in permeable membrane with dimension of 4 mm × 10 mm and the the thickness of 10 μm. The size of pore is 3 μm with the distance to the pale wall as much as 200, 300 and 500 μm. The type bio fluid employed for the NaCl and NaOH current was 20 mL/minute. The experiment showed that the bigger the distance to the plate, the small the transfer of mass. In the distance to the plate of 200, 300 and 500 µm, the diffusion was subsequently 5.05, 2.52, 1.5 mL/minute for concentration NaCl and 4.4, 1.84, 0.92 mL/menit for ion OH-. In the distance to the plate of 200, 300 and 500 µm, the pressure drop on membrane was subsequently 10303, 2155, 261 Pa for concentration NaCl and 9527, 1876, 241 Pa for ion OH-. While the pressure drop in pore was subsequently 3472, 2029, 261 Pa pada concentration NaCl and 2027, 1680, 160 Pa for ion OH-. In the distance to the plate of 200, 300 and 500 µm, the Reynold number on membrane was subsequently 7.55, 7.54, 7.49 for concentration NaCl and 7.5, 7.47, 7.41 for ion OH-, the. While the Reynold number in pore was subsequently 2.19x10-4, 1.36x10-4, 2.06x10-5 for concentration NaCl and 1.37x10-4, 1.14x10-4, 1.09x10-6 for ion OH-.


Ketersediaan
2019285616.151.Sal.pTersedia
Informasi Detail
Judul Seri
-
No. Panggil
616.151.Sal.p
Penerbit
Universitas Mataram : Fakultas Teknik Unram., 2019
Deskripsi Fisik
xi;45 Hlm; Illus; 21x29 cm
Bahasa
Indonesia
ISBN/ISSN
-
Klasifikasi
616.151
Tipe Isi
other
Tipe Media
computer
Tipe Pembawa
audio disc
Edisi
-
Subjek
PADA PERMUKAAN MEMBRAN
haemodialysis, diffusion, pattern of flow and dist
Info Detail Spesifik
-
Pernyataan Tanggungjawab
Salim AlQadri
Versi lain/terkait

Tidak tersedia versi lain

Lampiran Berkas
  • PENGARUH JARAK ANTAR PLATE PADA PERMEABILITAS ALIRAN BIOFLUIDA PADA PERMUKAAN MEMBRAN PERMEABLE. Effect Of Distance Between Plates On The Permeability Of Biofluida Flow On The Surface Of Permeable Membrane
Komentar

Anda harus login sebelum memberikan komentar

Perpustakaan Fakultas Teknik
  • Informasi
  • Layanan
  • Pustakawan
  • Area Anggota

Tentang Kami

Ruang Baca Fakultas Teknik

Kami menyedian Buku ajar ilmu teknik dan Tugas Akhir mahaiswa Fakultas Teknik Universitas Mataram

Cari

masukkan satu atau lebih kata kunci dari judul, pengarang, atau subjek

Donasi untuk SLiMS Kontribusi untuk SLiMS?

© 2025 — Senayan Developer Community

Ditenagai oleh SLiMS
Pilih subjek yang menarik bagi Anda
  • Karya Umum
  • Filsafat
  • Agama
  • Ilmu-ilmu Sosial
  • Bahasa
  • Ilmu-ilmu Murni
  • Ilmu-ilmu Terapan
  • Kesenian, Hiburan, dan Olahraga
  • Kesusastraan
  • Geografi dan Sejarah
Icons made by Freepik from www.flaticon.com
Pencarian Spesifik